Fluid - A/T: Service and Repair
Fluid Pan, Renew

FLUID PAN, RENEW

-

Open the hood and fit a suitable fender cover.

-

Raise the vehicle on a ramp.

-

Slacken the underfloor catalyst to downpipe clamps securing bolts.

-

Displace and reposition the olive clamps on the pipes.

-

Slacken the underfloor catalyst to intermediate silencer clamps securing bolts.

-

Displace the underfloor catalyst assembly rearwards to disconnect from the downpipes.

-

Displace and remove the olives from the downpipes.

-

Using a wire brush, clean the olives and downpipe joints.

-

Place a suitable piece of wood between the underfloor catalyst and the body for access.

-

Drain the transmission lubrication system.

-

Release and remove the fluid pan securing bolts.

-

Drain the residual fluid from the fluid pan.

-

Remove the fluid pan (1 Fig. 1) and gasket (2 Fig. 1).

-

Clean the fluid pan gasket, which can be re-used if in good condition.

-

Place the fluid pan gasket aside.

-

Remove the magnet (3 Fig. 1) from the fluid pan.

-

Clean the magnet and place on a clean surface.

-

Clean the transmission fluid pan joint face.

-

Clean the fluid pan.

-

Place the fluid pan aside.

-

Attach the magnet to the recess in a new fluid pan.

-

Fit and align a serviceable gasket to the fluid pan.