XJ-6 L6-3.6L (1989)
^
Install adaptor JAO (10 mm thread) and seal washer to the power booster, Fig. 1.
^
Connect the feed pipe to the adaptor.
^
Remove the most accessible plug from the adaptor.
^
Install and tighten the Pump and Master Cylinder Test Point (04) 6 mm thread and seal washer, Fig. 1.
Test Note 3 Thru 5
Test Note 3:
The pipe must always be connected to the gauge first. The test point adaptor has a one-way valve installed and incorrect installation could cause loss of
fluid at high pressure.
Test Note 4:
^
Disconnect the power hydraulics pump feed pipe at the valve block.
^
Install the relief valve adaptor (JRVO) 12 mm thread and washer to the valve block, Fig. 2.
^
Reconnect the power hydraulics feed pump to the adaptor.