jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Flap and Vacuum Components|Page 5532 > < Flap and Vacuum Components|Page 5530
Page 3
background image

will not operate until engine water temperature reaches 40°C (103°F).

Fans will automatically be on LO speed (1st) and switch to MED 1 (2nd) speed by camshaft. Only the two lowest fan speeds are available in
the heating mode.

Camshaft turns until stopped by full heat limit switch.

Camshaft movement depends on ambient and desired temperature set at temperature selector. Therefore, depending on conditions, flap
positions will vary to meet in-car temperature requirements. All air is passed through evaporator to be dehumidified.

HIGH & LO FAN SELECTION

Except for maintaining the given fan speed selected, the system's operation still remains automatic.

FULL COOLING MODE - AUTO

Flap Positions

Flap and Vacuum Components|Page 5532 > < Flap and Vacuum Components|Page 5530