jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Amplifier|Page 5795 > < Amplifier|Page 5793
Page 3
background image

Amplifier Circuit

When full cooling is selected, the temperature selector is placed at 65. This introduces a resistance into the circuit which lowers the current
and increases the voltage. Sensing the higher voltage, the amplifier allows the current flow through TR1, TR5 and TR3 which energizes
relay RSL1 which in turn allows current flow through the red lead and return to ground through the purple lead, rotating the motor and
hence the camshaft into the cooling mode. Under high ambient conditions, the Ranco thermostat is also overridden by the Ranco override
switch.

Amplifier|Page 5795 > < Amplifier|Page 5793