Timing Chain Tensioner: Service and Repair
Upper
Timing Chain Tensioner, Upper, Renew
-
Remove the timing cover.
-
Remove the upper timing chain (6 Fig. 1).
-
Remove the flanged bolts (3 Fig. 1) securing the tensioner pedestal.
-
Remove the pedestal I tensioner assembly and chain damper (1 Fig. 1).
-
Remove the tensioner pivot pin (2 Fig. 1) and remove the tensioner from the pedestal.
-
Clean the pivot pin.
-
Fit a new tensioner to the pedestal and fit the tensioner pivot pin. Secure the tensioner with the flanged bolts.
-
Align the damper to the tensioner and fit the damper/tensioner assembly to the engine.
-
Ensure that the damper does not foul the auxiliary shaft sprocket.
-
Finally tighten the securing bolts.
-
Fit the new timing chain.
-
Re-position the upper tensioner and temporarily secure to the upper dampers with an elastic band.
-
Renew the timing cover oil seal and refit the timing cover.