Instrument Cluster / Carrier: Service and Repair
Instrument Printed Circuit

INSTRUMENT PRINTED CIRCUIT 

 
RENEW 

Remove the instrument panel.   See: Instrument Panel Module, Renew
Remove the four instrument illumination bulb holders from the rear of the panel (1).
Note the position of all the fixing screws, connectors etc.
Remove the warning lamp retaining bar (2 Fig 3). 
Remove the nuts connecting the printed circuit to the tachometer (3 Fig 3) and speedometer (4 Fig 3). 
Remove the screws retaining the lens assembly. Remove the screws connecting the printed circuit to the centre gauge (5 Fig 3).
Remove the warning lamp holders (6 Fig 3). 
Ease the printed circuit clear of the locating spigots. 
Fit the new printed circuit to the panel locating spigots.

NOTE: Ensure the printed circuits are not torn or deformed, and all the connecting tags are correctly positioned under the terminals of components. Fit

the warning lamp bulb holders.

Fit and tighten the printed circuit and lens securing screws.
Fit and tighten the speedo/tachometer nuts. 
Refit the warning lamp retaining bar/earth. 
Refit the instrument illumination bulb holders. 
Refit the instrument panel to the car.

Lamp Out Indicator > < Instrument Panel Lens Assembly|Page 6051