RENEW 

Disconnect the battery earth cable.

Position the tilt steering column to the lowest position.

Remove the instrument panel finishers' securing screws and remove the central and side finishers (1 Fig. 1).

Remove the instrument panel to fascia securing screw cover plates and remove the screws securing the instrument panel to the fascia (2 Fig. 1).

Note:  To minimise the risk of damage and contamination, all repairs conducted on the Instrument Pack should be performed in a non-static dust free

environment.

Place a protective cover on a workbench and position instrument panel lens down onto the cover.

Remove the gauge illumination bulbs (1 Fig. 2).

Remove the printed circuit to instrument panel securing nuts and remove the printed circuit from the locating lugs (2 Fig. 2).

Remove the screws securing the rear cover to the lens/veneer panel (3 Fig. 2).

Invert the assembly and remove complete with the printed circuit from the rear cover.

Remove the tachometer from the rear cover housing (1 Fig. 3).

Fit the new tachometer to the rear cover housing. 

Reposition the printed circuit around the rear cover and fit the lens/assembly to the rear cover housing. 

Fit the rear cover to the lens/veneer panel and secure screws.

Fit the printed circuit to the rear housing and secure the nuts.

Fit the gauge illumination bulbs. 

Refit the instrument panel.

Reconnect the battery earth cable.