Oxygen Sensor: Description and Operation

PURPOSE

Oxygen sensor voltage signal is translated by ECM as exhaust gas oxygen content.  With this measurement, the ECM calculates air/fuel ratio.  By
comparing oxygen sensor signal with what it "knows" air/fuel ratio should be at any given moment, the ECM can make virtually instantaneous
adjustments throughout engine operating range.

OPERATION

Oxygen (Lambda) sensors generate voltage according to exhaust gas oxygen content.  The voltage range is approximately 0.1-1.0V.  Voltage increases
when oxygen content is low (rich) and decreases when oxygen content is high (lean).  The ECM determines air/fuel ratio based on voltage generated
and makes appropriate adjustments to maintain the optimum 14.7:1 ratio.  The difference in oxygen concentration changes greatly in the area of
optimum air/fuel ratio, resulting in large voltage changes that are easily calculated by the ECM.

Oxygen Sensor

CONSTRUCTION

Sensors incorporate a platinum coated ceramic zirconia tube which generates voltage if there is a difference in oxygen concentration between the inside
and outside of the tube.

To operate at peak efficiency, sensors must heat up to approximately 572 - 752°F (300 - 400°C).  A heating element, energized by the main relay, is
incorporated into each sensor to facilitate rapid attainment of operating temperature.  This system also prevents sensors from cooling down during
certain operating conditions such as periods of extended idle.

LOCATION

One each exhaust downpipe just below the exhaust manifolds.