XJR (X308) V8-4.0L SC (AJ26) (1998)
C5: CHECK HARNESS SHORT TO GROUND
With EM015 and EM014 disconnected, measure the insulation resistance between EM015/008 and ground EM014/009
-
Is the resistance > 10 M Ohms?
Yes
Do not reconnect
GO to [C6]
No
Inspect EM015, and EM014 for corrosion, bent/pushed back pins or locate and repair the harness/connector. Test the system for normal