11. Fitting a new internal harness is the reverse of the removal procedure noting the following

12. Lubricate EM046 "O" rings with transmission fluid prior to fitting

13. Tighten selector cable abutment fixings (2)

14. Tighten the INPUT speed sensor securing bracket fixing

NOTE:  MS fixing

15. Tighten the OUTPUT speed sensor securing bracket fixing

NOTE:  M6 fixing

NOTE:  Ensure extreme cleanliness & never reuse transmission fluid

16. Using a new gasket, install the fluid pan & tighten the fixings (22) as specified

Symptom Related Diagnostic Procedures|Page 6015 > < Symptom Related Diagnostic Procedures|Page 6013