XK-8 Convertible (X100) V8-4.0L (AJ26) (1997)
Connect scan tool
Record DTC(s), freeze frame data & GO to [B2]
B2: CHECK ECT SENSOR OPEN CIRCUIT
Disconnect connector P1004 & measure the resistance between the ECT sensor pins #1 & #2
-
Resistance > 30k Ohms?
-> Yes
Renew sensor & proceed to B6
-> No
GO to [B3]
B3: CHECK CONTINUITY HARNESS