Drive/Propeller Shaft: Technical Service Bulletins
Jaguar Vibration Analyzer - PDU 6000

920-01

V8 Sedan

DATE: 10/97

MODEL
1997 MY-ON XK8 Range
1998 MY-ON V8 Sedan

VIN
001001-ON
812256-ON

Jaguar Vibration Analyzer - PDU 6000

INTRODUCTION

Software Version PDU 6000, together with the Jaguar Vibration Analyzer (JVA), has been introduced to provide PDU with the capability of diagnosing
driveline vibrations. The Vibration User Guide supplied with this CD-ROM provides help and information on how to use the tool, and should be stored
at the rear of the PDU User Guide. The recently released PDU multimedia training CD-ROM also provides a training exercise on the use of the JVA.

REPAIR PROCEDURES

NOTE:

JVA road testing requires two technicians. Technician A must maintain road speed, transmission gear range and engine RPM, so the PDU can
capture vibration information. Technician B must capture up to 6 trace patterns in the PDU memory which will be printed out on the multimedia PC
using PDU Capture Version 2.0. Refer to the Jaguar Vibration Analyzer guide for additional information.

When PDU diagnoses a driveline vibration it will provide a fault description similar to that shown below:

1st Order Wheel Vibration

Repair Procedure 11

The top line indicates the nature of the fault, the second line refers to a list of recommended Repair Procedures for each fault type. These Repair
Procedure are contained in the diagnostic charts.

CONTACTING THE JAGUAR TECHNICAL HOTLINE

Many of the Repair Procedures may direct you to contact Jaguar Technical Hotline for further advice. In all instances, before contacting Technical
Support you should have printed all of the waveforms selected for analysis, together with the composite waveform if it was provided and a copy of the
fault report.

Repair Procedures for Problems Located using the Jaguar Vibration Analyzer

Introduction

The following details the recommended Procedures for locating and rectifying vibration problems diagnosed with the Jaguar Vibration Analyzer. Before
beginning a PDU vibration test, the following items should be visually inspected:

^

Wheels/Tires

^

Shock Absorbers

^

Road Springs

^

Exhaust Mounts

^

Engine/Transmission Mounts

^

Front and Rear Suspension Bushes

^

Vehicle Ride Height

^

Hand Brake Adjustment