XK-8 Convertible (X100) V8-4.0L (AJ26) (1997)
12. Remove three nuts securing glass lift motor/regulator assembly to body.
13. Feeding link lead and multiplug through water shedder (later moulded type), withdraw motor/regulator adjusters from body and remove assembly.
Installation
1. Guiding link lead through water shedder (later type), lower motor/regulator assembly through upper aperture and locate adjusters in body
apertures.