Position the generator aside to access the engine wiring harness clips.

44. RH side: Release the engine wiring harness.

-

Release the 5 clips.

45. Remove the engine wiring harness.

Installation

1. Install the engine wiring harness.
2. RH side: Attach the wiring harness.

-

Secure the clips.

3. Install the generator.

-

Tighten the nut to 25 Nm (18 lb.ft).

-

Tighten the nut and bolt to 40 Nm (30 lb.ft).

4. Connect the generator electrical connectors.

-

Tighten the nut to 12 Nm (9 lb.ft).

-

Secure the cover.

5. Install the generator cooling duct.

-

Tighten the screws.

6. Connect the engine oil temperature sensor electrical connector.
7. Connect the EOP sensor electrical connector.
8. Connect the starter motor solenoid electrical connector.

-

Tighten the new nut to 7 Nm (5 lb.ft).

9. Connect the starter motor battery positive and generator cables.

-

Tighten the nut to 10 Nm (7 lb.ft).

-

Secure the cover.

10. Connect the CKP sensor electrical connector.
11. Connect and secure the HO2S electrical connectors.

-

Secure the 2 clips.

12. Connect the A/C compressor electrical connector.
13. LH side: Attach the wiring harness.

-

Secure the clips.

14. Install the power steering pump mounting bracket.

-

Tighten the bolts to 25 Nm (18 lb.ft).