jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Quick Release Coupling|Page 2105 > < Quick Release Coupling
Page 1
background image

Fuel Line Coupler: Description and Operation
Quick Release Coupling - Push Connect

Quick Release Coupling - Push Connect

Disconnect

1. Relieve the fuel system pressure.

WARNING:
-

Place the vehicle in a quarantined area and arrange 'No Smoking/Petrol Fumes' signs about the vehicle.

-

Before any work is carried out on the fuel system, ground the vehicle to earth and maintain the ground connection until the work is
complete.

-

Do not smoke or carry lighted tobacco or open flame of any type when working on or near any fuel related components. Highly
flammable vapors are always present and may ignite. Failure to follow these instructions may result in personal injury.

-

Do not carry or operate cellular phones when working on or near any fuel related components. Highly flammable vapors are always
present and may ignite. Failure to follow these instructions may result in personal injury.

-

The fuel system remains pressurized for a long time after the ignition is switched off. The fuel pressure must be relieved before
attempting any repairs. Failure to follow these instructions may result in personal injury.

-

After carrying out repairs, the fuel system must be checked visually for leaks. Failure to follow these instructions may result in
personal injury.

-

This procedure involves fuel handling. Be prepared for fuel spillage at all times and always observe fuel handling precautions. Failure
to follow these instructions may result in personal injury.

-

If taken internally do not induce vomiting, seek immediate medical attention. Failure to follow these instructions may result in
personal injury.

-

If fuel contacts the eyes, flush the eyes with cold water or eyewash solution and seek medical attention.

-

Wash hands thoroughly after handling, as prolonged contact may cause irritation. Should irritation develop, seek medical attention.

2. Disconnect the push connect fitting.

-

Press the collar.

-

Disconnect the push connect fitting.

Connect

1. To connect.

-

Support the male stub.

-

Push the connector fitting onto the stub until an audible click can be heard.

-

Check the connection by a gentle tug test.

Quick Release Coupling|Page 2105 > < Quick Release Coupling