background image

Fig. 4  Mounting Angle Degree & Oil Level. Sankyo Compressors

7.

On all models, insert dipstick tool No. J29642-12 to its stop position. The stop is the angle near the top of dipstick. The bottom surface of the
angle must be flush with surface of oil filler hole.

8.

Remove dipstick, then compare to chart.

9.

Add or subtract oil until mid-range value is reached. For example if mounting angle is 10 ° and dipstick increment is 3, add oil until 7 is attained.

10.

Ensure seat and oil ring are secure and clean.

11.

Install oil filler plug, torque to 6-9 ft. lbs.

York Compressor

Fig. 5  Compressor Oil Level Check. York Compressor

Compressor oil level should be checked whenever system is discharged for service part replacement or after rapid loss of refrigerant.

1.

Isolate compressor as outlined previously.

2.

Slowly loosen crankcase oil check plug to relieve internal pressures, then after pressure is released, remove plug.

3.

Hold dipstick, tool No. J-29642-12 in a vertical position. then insert into check plug opening until dipstick bottoms in compressor. If necessary,
slightly rotate crankshaft to clear dipstick path.

4.

Remove dipstick and count number of dipstick increments covered with oil.

5.

When properly filled, compressor should contain 7-10 increments of oil.

6.

Add or remove oil as necessary. 