Commander 2WD V6-3.7L VIN K (2006)
20. Position the blend door actuator mounting bracket (5) and the mode door actuator mounting bracket (8) onto the left side of the air distribution
housing (1) and install the retaining screws (3 and 6). Tighten the screws to 2 N.m (17 in. lbs.).
21. Position the blend door actuator (4) and the mode door actuator (7) onto the mounting brackets and install the retaining screws (2). Tighten the
screws to 2 N.m (17 in. lbs.). If necessary, rotate the actuators slightly to align the splines on the actuator output shaft with those on the mode door
cam and the blend door stop.
22. Install the air distribution housing onto the HVAC housing.
Air Inlet Housing
HOUSING-AIR INLET
NOTE:
-
The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.
-
LHD model shown in illustration. RHD model similar.
DISASSEMBLY
1. Remove the air inlet housing (1) from the HVAC housing and place it on a workbench
2. Remove the two screws (2) that secure the recirculation door actuator (3) to the air inlet housing and remove the actuator.
NOTE: If the foam seal on the recirculation-air door or the air inlet housing is deformed or damaged, it must be replaced.
3. Carefully remove the recirculation-air door (4) from the air inlet housing.
ASSEMBLY