jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Removal and Replacement|Page 8388 > < Removal and Replacement|Page 8386
Page 12
background image

20. Position the blend door actuator mounting bracket (5) and the mode door actuator mounting bracket (8) onto the left side of the air distribution

housing (1) and install the retaining screws (3 and 6). Tighten the screws to 2 Nm (17 in. lbs.).

21. Position the blend door actuator (4) and the mode door actuator (7) onto the mounting brackets and install the retaining screws (2). Tighten the

screws to 2 Nm (17 in. lbs.). If necessary, rotate the actuators slightly to align the splines on the actuator output shaft with those on the mode door
cam and the blend door stop See: Air Door/Air Door Actuator / Motor/Service and Repair/Blend Door Actuator - Installation and See: Air
Door/Air Door Actuator / Motor/Service and Repair/Mode Door Actuator - Installation.

22. Install the air distribution housing onto the HVAC housing .

Front Air Inlet Housing

HOUSING-AIR INLET

NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.

1. Position the recirculation-air door (4) into the air inlet housing (1).

CAUTION: Make sure that the recirculation-air door pivot shaft is properly seated in the pivot seats located on the air inlet housing.

2. Install the recirculation door actuator (3) onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the recirculation door pivot shaft See: Air Door/Air Door Actuator / Motor/Service and Repair/Recirculation Door
Actuator - Installation.

3. Install the two screws (2) that secure the recirculation door actuator to the air inlet housing. Tighten the screws to 2 Nm (17 in. lbs.).
4. Install the air inlet housing onto the HVAC housing .

Front HVAC Housing

HOUSING-HVAC ASSEMBLY

CAUTION: Be certain to adjust the refrigerant oil level when servicing the A/C refrigerant system See: Service and Repair/Refrigerant Oil
Level. Failure to properly adjust the refrigerant oil level will prevent the A/C system from operating as designed and can cause serious A/C
compressor damage.

Removal and Replacement|Page 8388 > < Removal and Replacement|Page 8386