7. Remove the tape or plugs from the evaporator tube fittings and all of the expansion valve ports.
8. Lubricate new rubber O-ring seals with clean refrigerant oil and install them on the evaporator tube fittings. Use only the specified O-rings as they

are made of a special material for the R-134a system. Use only refrigerant oil of the type recommended for the A/C compressor in the vehicle.

9. Install the A/C expansion valve (2) onto the evaporator tube tapping block (3) located at the front of the HVAC housing (4).

10. Install the two bolts (1) that secure the A/C expansion valve to the evaporator tube tapping block. Tighten the bolts to 11 N.m (97 in. lbs.).

11. Install the evaporator temperature sensor (2).
12. Install the blower motor resistor or power module (4), depending on application.
13. Install the blower motor (3).
14. Install the HVAC wiring harness (1) onto the HVAC housing (5) and engage the two wire harness retainers to the housing.
15. Connect the HVAC wire harness to the evaporator temperature sensor and blower motor resistor or power module (depending on application).
16. Connect the blower motor wire harness to blower motor resistor or power module (depending on application).

Removal and Replacement|Page 5565 > < Removal and Replacement|Page 5563