jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Brake Proportioning/Combination Valve|Description and Operation|Page 6075 > < Brake Hoses|Page 6071
Page 1
background image

Brake Proportioning/Combination Valve: Description and Operation

GENERAL  INFORMATION 

The combination valve contains a pressure differential valve and switch and a rear brake proportioning valve. The valve is not repairable. It must
be replaced if diagnosis indicates this is necessary. 

PRESSURE DIFFERENTIAL SWITCH

The pressure differential switch is connected to the brake warning light. The switch is actuated by movement of the switch valve. The switch
monitors fluid pressure in the separate front/rear brake hydraulic circuits. 

A decrease or loss of fluid pressure in either hydraulic circuit will cause the switch valve to shuttle to the low pressure side. Movement of the valve
pushes the switch plunger upward. This action closes the switch internal contacts completing the electrical circuit to the red warning light. The
switch valve will remain in an actuated position until repairs are made. 

PROPORTIONING VALVE

The rear proportioning valve is used to balance front-rear brake action. The valve allows normal fluid flow during moderate effort brake stops.
The valve only controls (meters) fluid flow during high effort brake stops.

Brake Proportioning/Combination Valve|Description and Operation|Page 6075 > < Brake Hoses|Page 6071