jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

All Other Service Bulletins for Stabilizer Bushing: > < A/C - Automatic Temperature Control Setting Changes
Page 2
background image

IT IS IMPORTANT THAT THE FOLLOWING AZC INITIALIZATION PROCESS IS NOT INTERRUPTED. DO NOT CHANGE ANY AZC
OR IGNITION SWITCH SETTINGS WHILE THE INITIALIZATION PROCESS IS OCCURRING.

6.

Move the Mode selector, on the AZO assembly, to any position other than the OFF position.

7.

Turn the ignition switch to the ON position.

8.

Allow the AZC assembly to initialize (learn). This may take approximately one minute. During this time the technician may notice changes in fan
speed and air being routed through the different HVAC vents. Once these changes have stopped the AZO initialization process is complete.

9.

Turn the ignition switch to the OFF position.

NOTE:

IF THE AZC INITIALIZATION PROCESS IS INTERRUPTED, THEN A BATTERY DISCONNECT MUST BE PERFORMED PRIOR TO
ATTEMPTING ANOTHER AZC INITIALIZATION.

POLICY:
Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:

Labor Operation No:

24-75-01-93

AZC, Module - Replace

0.3 Hrs

FAILURE CODE:

P8

New Part

All Other Service Bulletins for Stabilizer Bushing: > < A/C - Automatic Temperature Control Setting Changes