Magnetic Switch Hold In Test
This test must be performed in less than 10 seconds to prevent coil from burning.
1.
Disconnect field coil wire from M terminal of magnetic switch.
2.
Connect a 12 volt battery between S terminal and body.
3.
If pinion remains out, system is satisfactory.
4.
If pinion moves in, hold-in circuit is open. Replace magnetic switch.