Accumulator HVAC: Service and Repair

REMOVAL

WARNING:  REVIEW THE WARNINGS AND CAUTIONS IN THE FRONT OF THIS SECTION BEFORE PERFORMING THE
FOLLOWING OPERATION.

1. Disconnect and isolate the battery negative cable.
2. Recover the refrigerant from the refrigerant system.
3. Unplug the wire harness connector from the low pressure cycling clutch switch.

Fig.13 A/C Low Pressure Switch

4. Loosen the screw that secures the accumulator retaining band to the support bracket on the dash panel.
5. Disconnect the suction line from the accumulator outlet tube refrigerant line fitting. Install plugs in, or tape over all of the opened refrigerant line

fittings.

6. Disconnect the accumulator inlet tube refrigerant line fitting from the evaporator outlet tube. Install plugs in, or tape over all of the opened

refrigerant line fittings.

7. Pull the accumulator and retaining band unit forward until the screw in the band is clear of the slotted hole in the support bracket on the dash

panel.

8. Remove the accumulator from the vehicle.

INSTALLATION

WARNING:  REVIEW THE WARNINGS AND CAUTIONS IN THE FRONT OF THIS SECTION BEFORE PERFORMING THE
FOLLOWING OPERATION.

1. Install the accumulator and retaining band as a unit by sliding the screw in the band into the slotted hole in the support bracket on the dash panel.
2. Remove the tape or plugs from the refrigerant line fittings on the accumulator inlet tube and the evaporator outlet tube. Connect the accumulator

inlet tube refrigerant line coupler to the evaporator outlet tube.

3. Tighten the accumulator retaining band screw to 5 Nm (45 in. lbs.).
4. Remove the tape or plugs from the refrigerant line fittings on the suction line and the accumulator outlet tube. Connect the suction line to the

accumulator outlet tube refrigerant line coupler.

5. Plug the wire harness connector into the low pressure cycling clutch switch.
6. Connect the battery negative cable.
7. Evacuate the refrigerant system.
8. Charge the refrigerant system. 

Accumulator HVAC|Specifications|Page 4783 > < Accumulator HVAC|Specifications|Page 4781