Housing Assembly HVAC: Overhaul

DISASSEMBLY

1. Remove the HVAC housing from the vehicle and place it on the workbench. See: Removal and Replacement 
2. Unplug the vacuum harness connectors from the mode and recirculation door actuators and the recirculation door actuator. Refer to Air Door

Actuator/Motor/Service and Repair/Procedures. See: Air Door/Air Door Actuator / Motor/Service and Repair

3. Disengage the vacuum harness from any routing clips located on the lower half of the HVAC housing.
4. Remove the blower motor and blower wheel unit from the HVAC housing. Refer to Heating and Air Conditioning/Blower Motor/Service and

Repair/Procedures. 

5. Pop out the grommet on the vacuum supply line and slide hole in housing.
6. Carefully remove the foam seals from the heater core and evaporator coil tube mounting flange of the HVAC housing. If the either seal is

deformed or damaged it must be replaced.

7. Use a screwdriver to pry off the four snap clips that help secure the upper and lower HVAC housing halves together.
8. Remove the screws that secure the upper and lower HVAC housing halves together.
9. Carefully separate the upper HVAC housing from the lower half.

ASSEMBLY

1. Assemble the upper HVAC housing half to the lower half. During assembly, be certain of the following.

a. That each of the mode door pivot shaft ends and the two temperature blend door shafts are properly engaged in there pivot holes.
b. That the blower motor venturi ring is properly indexed and installed.
c. If the unit is equipped with air conditioning, that the evaporator coil tube rubber seal is properly positioned in the grooves in both the upper

and lower HVAC housing halves.

2. Install the screws and four snap clips that secure the upper and lower HVAC housing halves to each other. Tighten the screws to 2.2 Nm (20 in.

lbs.).

3. Install the blower motor and wheel unit in the HVAC housing. Refer to Heating and Air Conditioning/Blower Motor/Service and

Repair/Procedures. 

4. Install the foam seals on the flanges around the heater core and evaporator coil tube mounting flange of the HVAC housing.
5. Insert the vacuum supply line and connector through the foam seal on the heater core and evaporator coil tube mounting flange of the HVAC

housing. Check that the vacuum grommet is securely seated into the housing hole flange.

6. Engage the vacuum harness to the routing clips and plug in the vacuum harness connector at the floor door actuator and, if the unit is so equipped,

at the recirculation air door actuator. Refer to Air Door Actuator/Motor/Service and Repair/Procedures. See: Air Door/Air Door Actuator /
Motor/Service and Repair