jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Coolant Level Indicator Lamp > < Compass Calibration|Page 6594
Page 5
background image

1. Using the Variance Settings map, find your geographic location and note the zone number.
2. Turn the ignition switch to the On position. If the compass/thermometer data is not currently being displayed, momentarily depress and release the

C/T push button to reach the compass/thermometer display

3. Depress the Reset push button and hold the button down until "VARIANCE = XX" appears in the display. This takes about five seconds.
4. Release the Reset push button. "VARIANCE =XX " will remain in the display. "XX" equals the current variance zone setting.
5. Momentarily depress and release the Step push button to step through the zone numbers, until the zone number for your geographic location

appears in the display.

6. Momentarily depress and release the Reset push button to enter the displayed zone number into the CMTC module memory.
7. Confirm that the correct directions are now indicated by the compass.

Coolant Level Indicator Lamp > < Compass Calibration|Page 6594