Wrangler 4WD L4-150 2.5L VIN P MFI (1998)
Oxygen Sensor: Testing and Inspection
OXYGEN (O2S) SENSORS
To perform a complete test of the O2S sensors and their circuitry refer to the DRB scan tool and appropriate Powertrain Diagnostics Procedures.
To test the O2S sensors only, refer to the following:
Fig. 28 Upstream Oxygen Sensor Location
The upstream O2S sensor is located on the exhaust downpipe (Fig. 28).
Fig. 29 Downstream Oxygen Sensor Location
The downstream O2S sensor is located near the outlet end of the catalytic converter (Fig. 29).
Each O2S heating element can be tested with an ohmmeter as follows:
Disconnect the O2S sensor connector. Connect the ohmmeter test leads across the white wire terminals of the sensor connector. Resistance should
be between 5 and 7 ohms. Replace the sensor if the ohmmeter displays an infinity (open) reading.