Wrangler 4WD L4-150 2.5L VIN P MFI (1998)
Generator: Service and Repair
REMOVAL
WARNING:DISCONNECT NEGATIVE CABLE FROM BATTERY BEFORE REMOVING BATTERY OUTPUT WIRE (B+ WIRE)
FROM GENERATOR. FAILURE TO DO SO CAN RESULT IN INJURY OR DAMAGE TO ELECTRICAL SYSTEM.
1. Disconnect negative battery cable at battery
2. Remove generator drive belt.
Remove/Install Generator Connectors - Typical
3. Remove nuts from harness hold-down, battery terminal, ground terminal and 2 field terminals. Remove wire connectors. A typical generator wiring
harness is shown. Wiring harness routing as shown may be slightly different depending on vehicle model and/or engine.
Generator Remove/Install
4. Remove upper and lower generator mounting bolts.
5. A slide bushing is pressed into the rear mounting ear of generator. Pry or drive this spacer rearward about 1/8 inch to loosen generator from upper
mounting bracket. This will allow generator to be tilted for removal.
6. Remove generator from vehicle.