Amanti V6-3.5L (2006)
3. Illumination stops condition
a. IGN key hole is illuminated
b. IGN ON or Entered arm mode by RKE
c. IGN key hole illumination is turned off immediately key hole illumination = OFF
DEFROSTER TIMER
1. Condition 1
a. Alternator level high & defroster is OFF
(Defroster relay = OFF and defogger activity = OFF)
b. Defroster is activated (defroster SW = ON)
c. Defroster outputs are turned ON
2. Condition 2
a. Alternator level high & defroster is ON
b. Defroster SW Input pushed again or T1 delay has elapsed since defroster has been turned on
c. Defroster outputs are turned OFF
3. Condition 3
If alternator input is changed to low, defroster outputs should be turned OFF immediately.
DECAYED ROOM LAMP
1. Condition 1
a. (IGN1 is OFF) & (door are closed) & (room lamp is OFF)
b. A door is opened more than 0.1 sec (all door not closed = ON)
c. Room lamp is turned ON
2. Condition 2
a. (IGN1 is OFF) & (a door at least is open)
b. All door are closed (all door not closed = OFF)
c. The power of room lamp is reduced from 100% to 75% to indicate that the door is closed. And then the lamp is slowly decayed off during 5 - 6
sec.
3. Condition 3
a. (IGN1 is OFF) & (room lamp is decaying)
b. IGN1 ON
c. Stop decaying operation immediately
4. Condition 4
a. (Room lamp is OFF) & (IGN1 is OFF) & (door are closed).
b. Unlock by RKE.
c. Room lamp is turned ON for 30 sec.