Amanti V6-3.5L (2006)
Inspection Sheet
LOAD TEST
Regulating Voltage Table
1. When discharging the battery during 15 seconds at half currency of Cold Cranking Ampere (CCA), the voltage of the battery should be as shown
above.
2. When the voltage is not within specification, repeat the load test again, and re-charge.
3. If the battery is left alone for 2 hours after re-charging and its output is over 12.5 V, and the voltage after a load test is over the standard value.the
battery can be used.
BATTERY VISUAL INSPECTION (2)
1. Make sure the ignition switch and all accessories are in the OFF position.