kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Variable Induction Control Actuator|Specifications|Page 4321 > < Variable Induction Control Actuator|Specifications|Page 4319
Page 1
background image

Variable Induction Control Actuator: Description and Operation

VARIABLE INTAKE SOLENOID (VIS) VALVE

DESCRIPTION

Variable Intake Solenoid (VIS) Valve is installed on the intake manifold and isolates or not the one bank from the other banks to improve the intake
efficiency.

1. Low/Middle Speed: VIS Valve Close -> Resonation Effect -> Improving Intake Efficiency
2. High Speed: VIS Valve Open -> Improving Intake Inertia Effect -> Improving Intake Efficiency

Specification

Specification

Variable Induction Control Actuator|Specifications|Page 4321 > < Variable Induction Control Actuator|Specifications|Page 4319