kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Battery Diagnostic Flow|Page 5599 > < Battery Diagnostic Flow|Page 5597
Page 1
background image

Battery: Testing and Inspection
Battery Test Procedure

BATTERY TEST PROCEDURE

1. Connect the tester to the battery.

-

Red clamp to battery positive (+) terminal.

-

Black clamp to battery negative (-) terminal.

CAUTION:  Connect clamps securely. If "CHECK CONNECTION" message is displayed on the screen, reconnect clamps securely.

2. The tester will ask if the battery is connected "IN A VEHICLE" or "OUT OF A VEHICLE". Make your selection by pressing the arrow buttons;

then press ENTER.

3. Choose either CCA or CCP and press the ENTER button.

NOTE:
-

CCA : Cold cranking amps, is an SAE specification for cranking batteries at -18 °C (0 °F).

-

CCP: Cold cranking amps, is an SAE specification for Korean manufacturer's for cranking batteries at -18 °C (0 °F).

Battery Diagnostic Flow|Page 5599 > < Battery Diagnostic Flow|Page 5597