kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 7418 > < Diagram Information and Instructions|Page 7416
Page 4
background image

1 Immediately stop control and set its position to the limit position of its proceeding direction if input of over 6 pulses in 2 sec. is not fed during
memory playing after attaching battery (Setting Limit on the opposite is the same).
2 Once a certain limit is set, memory playing that goes beyond set range is not allowed to run to prevent motor damage by mechanical lock
3 Renew limit position if pulses are fed normally beyond its limit position Already set by manual operation

Detecting error or handling error

1. Detecting error for seat

Unit judges motor to be error if the following conditions occur during manual SW operation,Easy Access Funtion gearing operation or memory
playing.
1 Error when pulse is not fed

* Stop the related motor if an error is detected during playing or Easy Access Funtion gearing operation.
* Stop the corresponding motor if an error is detected during manual operation (Excluding slide motor).
2 If seat sensor Vcc below 1V is detected by 40ms,
=> Return if seat sensor Vcc is 4V or more.
* Stop all seat motors running if seat sensor Vcc error is detected during playing or Easy Access Funtion gearing operation. (No buzzer output)

2. Handling error

If errors in the above are discovered, regard them as harness disconnection or sensor failure, and conduct the following measures.
A. Stop auto control (play or Easy Access Funtion gearing operation) if it is under auto control and set off buzzer 10 times (however, have motors

other than the one with an error operate normally).

B. Set off alarm again in case of recurrence of error after restoration of a motor with an error.
C. Complete alarm 10 times though it comes back to normal during error alarm.
D. Stop alarm if receiving memory recall or play order, and set off buzzer in the corresponding function.
E. Manual operation control is allowed even for a motor with errors.
F. Set off buzzer if memory or play order is received even during error.
G. The timing to lift auto control suspension is when repair for the failing motor is completed, and the criteria for the completion point are as

follows:
Seat: if signal input is normal with over 6 pulses within a sec. from position sensor of a motor with an error caused by manual SW