Borrego 4WD V6-3.8L (2009)
Power Window Timer Function
1. It is a message from IPM. (Message : After run Ctrl).
2. Under the condition "IGN ON -> IGN OFF", Power Window SW Control Function lasts for "30 sec". But, it immediately terminates to OFF when
front door is opened.
Safety Power Window
1. Drive door and assist door apply to, In condition of IGN2 On or After Run Ctrl (CAN) On Door door is controlled by DDM, assist door is
controlled by CAN message (message :AD Window Ctrl)
2. P/WDW main SW (DDM) control signal of down, auto up, auto down.
Power Window control
1. P/Window enable signal on condition
A. P/Window timer(from IPM) ON or IGN2 (DDM itself) ON
(When satisfied with one of two condition)
2. Up/down control signal
A. P/WDW timer(from IPM) ON or IGN2 (DDM itself) ON
* P/WINDOW TIMER(FROM IPM) OFF & IGN2(DDM ITSELF) OFF, independently of Switch's state UP SIGNAL and DOWN SIGNAL are
OFF state preservation