Optima L4-2.4L (2001)
Alternator Brush: Service and Repair
Brush Replacement
1. Measure the length of the brush protrusion shown in the illustration, and replace the brush if the measured value is below the limit value.
Limit: 2 mm (0.079 in.) or less
2. The brush can be removed if the solder of the brush lead wire is removed.
3. When installing a new brush, insert the brush into the holder, and then solder the lead wire.