Blower Motor: Service and Repair

Removal

1. Discharge refrigerant from A/C system. (Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper

procedures.)

2. Disconnect inlet and outlet pipe from evaporator.

Note:  Immediately plug all open fittings to keep moisture out of system.

3. Remove cover and drain hose.

4. Remove instrument panel and disconnect wiring harness connector.
5. Remove blower unit.

Installation

1. Install in reverse order of removal.
2. Evacuate refrigerant system. (Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.)
3. Charge A/C system. (Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.)