kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1034 > < Diagram Information and Instructions|Page 1032
Page 9
background image

hold the leads together and adjust the ohmmeter to read zero ohms.

C. Connect the other lead to the other end.
D. If the self-power test lamp glows, there is continuity. If you are using an ohmmeter, low or zero resistance means good continuity.

3. TESTING FOR SHORT TO GROUND

A. Disconnect the battery negative terminal.
B. Connect one lead of a self-powered test lamp or an ohmmeter to the fuse terminal on the load side.
C. Connect the other lead to a ground.
D. Beginning near the fuse block move the harness from side to side. Continue this procedure(about six inches apart) while watching the

self-powered test lamp or ohmmeter.

E. When the self-powered test lamp glows, or ohmmeter registers, there is a short to a ground in the wiring near that point.

4. TESTING FOR A SHORT WITH A SHORT FINDER

A. Remove the blown fuse. Leave the battery connected.
B. Connect the short finder across the fuse terminals.
C. Close all switches in series in the circuit that is being testing.
D. Turn on the short circuit locator. It sends pulses of current to the short. This creates a pulsing magnetic field around the wiring between the

fuse box and the short.

Diagram Information and Instructions|Page 1034 > < Diagram Information and Instructions|Page 1032