Sephia LS Sedan L4-1.8L (1998)
Condenser HVAC: Service and Repair
REMOVAL
1. Discharge refrigeration system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.
2. Remove liquid pipes.
3. Remove condenser as shown in figure.
NOTE:
a. Insert protector such as cardboard between condenser and radiator.
b. Immediately plug open fittings to keep moisture out of system.
INSTALLATION
1. Install condenser in reverse order of removal.
NOTE:
a. Apply clean compressor oil to O-rings before connecting fittings.
b. Do not apply compressor oil to fitting nuts.
c. Remove protector before installing radiator brackets.