kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1230 > < Diagram Information and Instructions|Page 1228
Page 6
background image

1. Connect one lead of test light to known good ground, or if you are using a voltmeter, be sure you connect its negative lead to ground.
2. Connect the other lead of the test light or voltmeter to the point you want to check.
3. If the test light glows, there is voltage present. If you are using a voltmeter, note the voltage reading. It should be within one Volt of measured

battery voltage. A loss of more than one Volt indicates a problem.

Testing For Continuity

Testing For Continuity

This test checks for continuity within a circuit. When testing for continuity at a connector, you may not have to separate the two halves of the connector.
Instead, probe the connector from the back. Always check both sides of the connector because dirt and corrosion between contact surfaces can cause
electrical problems.

1. Disconnect the negative cable from the vehicle battery.
2. If you are using an ohmmeter, hold the leads together and adjust the ohmmeter to read zero Ohms.
3. Connect one lead of self-powered test light or ohmmeter to one end of the part of the circuit you wish to test.
4. Connect the other lead to the other end.
5. If the self-powered test light glows, there is continuity. If you're using an ohmmeter, low or no resistance means good continuity.

Testing For Voltage Drop

Testing For Voltage Drop

This test checks for voltage drop along a wire, or through a connection or switch.

1. Connect the positive lead of a voltmeter to the end of the wire (or to the side of the connector or switch) closest to the battery.
2. Connect the negative lead to the other end of the wire (or the other side of the connector or switch).
3. Operate the circuit.
4. The voltmeter will show the difference in voltage between the two points. A difference, or drop of more than 0.5 Volts, may indicate a problem.

Check the circuit for loose or dirty connections.

Diagram Information and Instructions|Page 1230 > < Diagram Information and Instructions|Page 1228