Fault Code

2. How to read self-diagnostic code

After the display panel flickers three times every 0.5 seconds, the corresponding fault code flickers on the setup temperature display panel every
0.5 seconds
 and will show two figures. Codes are displayed in numerical format.

3. Fault code display.
4. If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.
5. Fail Safe

1. In-car temperature sensor: Control with the value of 25 °C (77 °F)
2. Ambient temperature sensor: Control with the value of 20 °C (67 °F)
3. Evaporator temperature sensor: Control with the value of -2 °C (28.4 °F)
4. Humidity sensor: Doesn't control.
5. Photo sensor: None correction
6. Temperature control actuator (Air mix potentiometer):

-

If temperature set 17 °C - 24.5 °C, fix at maximum cooling position.

-

If temperature set 25 °C - 32 °C, fix at maximum heating position.

7. Mode control actuator (Direction potentiometer):

-

Fix vent position, while selecting vent mode.

-

Fix defrost position, while selecting all except vent mode.