kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Variable Induction Control Actuator|Specifications|Page 4490 > < Variable Induction Control Actuator|Specifications|Page 4488
Page 1
background image

Variable Induction Control Actuator: Testing and Inspection

VARIABLE INTAKE SOLENOID (VIS) VALVE

INSPECTION

FUNCTION AND OPERATION PRINCIPLE

Variable lntake Solenoid (VIS) Valve is installed on the intake manifold and is used to improve intake efficiency.

1. Low/Middle Speed: VIS Valve Close -> Resonation Effect -> Improving lntake Efficiency 
2. High Speed: VIS Valve Open -> Improving Intake Inertia Effect -> Improving Intake Efficiency

Specification

SPECIFICATION

Variable Induction Control Actuator|Specifications|Page 4490 > < Variable Induction Control Actuator|Specifications|Page 4488