Sorento 4WD V6-3.5L (2011)
^ ONLY use approved ECM upgrade software designated for the correct model, year.
*NOTICE
ROM Table Information:
Upgrade event #147
*NOTICE
To verify the vehicle is affected, be sure to check the Calibration Identification of the vehicle's ECU's ROM ID and reference the Information Table as
necessary.
1. Connect the power supply cable to the GDS tool or to the diagnostic terminal with the GDS docked.
*NOTICE
If attempting to perform ECM upgrade with power supply cable disconnected from the GDS tool, be sure to check that the GDS tool is fully charged
before ECM upgrade. If the GDS tool is not fully charged, failure to perform the ECM upgrade may occur. Therefore, it is strongly recommended that
the power supply be connected to the GDS tool.
2. Connect the USB cable between the VCI and the GDS tool.
NOTICE
When performing the ECM upgrade using the GDS tool, wireless communication between the VCI and GDS tool is not available. Connecting the VCI to
the GDS tool with the USB cable is required.