kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Refrigerant Oil|Capacity Specifications|Page 5736
Page 1
background image

Refrigerant Oil: Testing and Inspection

Oil Specification

1. The HFC-134a system requires synthetic (PAG) compressor oil whereas the R-12 system requires mineral compressor oil. The two oils must never

be mixed.

2. Compressor (PAG) oil varies according to compressor model. Be sure to use oil specified for the model of compressor.

Handling of Oil

1. The oil should be free from moisture, dust, metal powder, etc.
2. Do not mix with other oil.
3. The water content in the oil increases when exposed to the air. After use, seal oil from air immediately. (HFC-134a Compressor Oil absorbs

moisture very easily.)

4. The compressor oil must be stored in steel containers, not in plastic containers.

Compressor oil check

The oil used to lubricate the compressor is circulating with the refrigerant.
Whenever replacing any component of the system or a large amount of gas leakage occurs, add oil to maintain the original amount of oil.

Oil total volume in system :100±10cc (3.52±0.34 fl.oz)

Oil Return Operation

There is close affinity between the oil and the refrigerant.
During normal operation, part of the oil recirculates with the refrigerant in the system. When checking the amount of oil in the system, or replacing any
component of the system, the compressor must be run in advance for oil return operation. The procedure is as follows:

1. Open all the doors and the engine hood.
2. Start the engine and air conditioning switch to "ON" and set the blower motor control knob at its highest position.
3. Run the compressor for more than 20 minutes between 800 and 1,000 rpm in order to operate the system.
4. Stop the engine.

Replacement of Component Parts

When replacing system component, add the following amount of oil to the component to be installed.

For compressor Replacement, subtract the volume of oil drained from the removed compressor from the specified volume, and drain the calculated
volume of oil from the new compressor:
The specified volume - volume of removed compressor = volume to drain from the new compressor.

NOTE:

-

Even if no oil is drained from the removed compressor, don't drain more than 50cc from new compressor.

Refrigerant Pressure Sensor / Switch, HVAC > < Refrigerant Oil|Capacity Specifications|Page 5736