Spectra5 L4-2.0L (2005)
Power Door Lock Actuator: Testing and Inspection
Front Continuity Test
FRONT DOOR LOCK ACTUATOR INSPECTION
1. Remove the front door trim panel.
2. Disconnect the 6P connector from the actuator.
3. Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only
momentarily