Spectra5 L4-2.0L (2005)
Air Door Actuator / Motor: Testing and Inspection
Intake Actuator
INTAKE ACTUATOR
INSPECTION
1. Verify that the fresh and recalculation actuator operates to the fresh position when connecting 12 V to the terminal I and grounding terminal 2.
2. Verify that the fresh and recalculation actuator operates to the recirculation position when connecting in the reverse.