Bend the ends of the tool blades in slightly to fit into the two release holes at the sides of each terminal.

10.

Cut the # 4 terminal wire (White) 2-2.5 inches from the terminal.

11.

Prepare new same color wire with oxygen sensor connector terminal (larger than PCM side terminal) and slide the heat shrinking tube onto the
wire allowing room to splice and solder.

12.

Strip the ends of wire insulations put a splice clip over the exposed wires and crimp it Solder the splice with low temperature solder being careful
not to overheat the wires or heat shrinking tube.

*NOTICE:

Verify that the splice clip holds the exposed wires securely.

13.

Slide heat shrinking tubes over the splice clips and apply heat to them.

NOTICE:

-

Heating temperature required: (750°F)

-

Center the heat shrinking tube over the crimped connection and heat it until glue melts out of each end.

-

Be careful not to damage the tube and the wire insulation from excessive heating.

14.

Repeat steps 10 through 13 on the # 1 terminal (Blue with orange stripe).