kia Workshop Repair Guides

Kia Workshop Service and Repair Manuals

Electrical Specifications|Page 2632 > < Electrical Specifications|Page 2630
Page 2
background image

1. Using an ohmmeter, check the primary coil's resistance. If not within specification, replace coil.

-

Remember that the unit has two coil assemblies, so there are two primaries to check. Connect one lead of the ohmmeter to the to the positive
(+) terminal and the other lead to each negative (-) terminal.

Primary coil resistance: 0.55 - 0.60 ohms @ 68°F (20°C)  

2. Using an ohmmeter, check the secondary coil's resistance. If not within specification, replace coil.

-

Remember that you must check both the top and the bottom secondary coil's resistance. If one is out of specification replace whole unit.

Secondary coil resistance: 13 - 15k ohms @ 68°F (20°C)

Electrical Specifications|Page 2632 > < Electrical Specifications|Page 2630