Testing For Voltage

This test measures voltage in a circuit. When testing for voltage at a connector, you may not have to separate the two halves of the connector. Instead,
probe the connector from the back. Always check both sides of the connector because dirt and corrosion between its contact surfaces can cause electrical
problems.

1. Connect one lead of a test light to known good ground, or if you are using a voltmeter, be sure you connect its negative lead to ground.
2. Connect the other lead of the test light or voltmeter to the point you want to check.
3. If the test light glows, there is voltage present. If you are using a voltmeter, note the voltage reading. It should be within one Volt of measured

battery voltage. A loss of more than one Volt indicates a problem.

Testing For Voltage Drop

Testing For Voltage Drop

This test checks for voltage drop along a wire, or through a connection or switch.