Fuse: Customer Interest
Auxiliary Heater Fuse - Failure

30/06/95

80/01/95/US

SUBJECT
Auxiliary Heater Fuse Failure

MODEL
Defender 90/110

AFFECTED VEHICLES 
LP 
LH 
LJ
LD All

DETAIL

It has come to our attention that in extremely cold ambient temperatures, the 5 amp auxiliary heater fuse may blow. This pertains to models equipped
with the passenger side auxiliary heater (underneath passenger seat).

Normal current draw of the motor is 3.7-3.8 amps. At temperatures below -13 deg.F (-25 deg.C) the draw can exceed 5 amps on spin up, causing the fuse
to blow.

Defender Electrical Engineering have approved the use of a 7.5 amp fuse in place of the 5 amp fuse to address this condition.

ACTION REQUIRED

Upon customer complaint of periodic fuse failure follow procedure below.

PARTS INFORMATION

RTC 4498 7.5 amp fuse

PROCEDURE

Follow fuse replacement procedure in Workshop Manual (86.70.02).

WARRANTY

Normal policy and procedures apply.

COMP. CODE

7Z2S

SR0

86.70.02 Fuse renew 0.10 hour.