landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Hazard Warning Indicator > < Hazard Flasher - Failure Without Fuse Blowing
Page 1
background image

Hazard Warning Flasher: All Technical Service Bulletins
Hazard Flasher - Failure Without Fuse Blowing

No: 86/22/97/NAS

Ref:

Issue: 1

Date: 09/19/97

Hazard Circuit Flasher Failure

AFFECTED VEHICLE RANGE:
DEFENDER (LD)

VA999307 upward

SITUATION:

HAZARD FLASHER FAILS WITHOUT FUSE BLOWING

Under certain conditions the hazard unit could suffer internal electrical damage even if the 30 Amp "E3" fuse does not blow.

RESOLUTION:

CAREFUL CHECK OF FUSE AND FLASHER UNIT WHEN AFFECTING REPAIRS

Whenever repairs to the hazard warning system, such as wiring, lamps etc, have been performed, the 30 Amp fuse in the under-bonnet fusebox should be
checked, together with the hazard unit (PRC8876) for full functionality.

PARTS INFORMATION:

PRC 8876

Hazard Flasher Unit

WARRANTY CLAIMS:

86.55.12

Time 0.30 hrs.
Check and replace hazard warning unit

COMP CODE:

7M5V

Normal warranty policy and procedures apply

REPAIR PROCEDURE

NOTE:

Make sure to check both the 30 Amp fuse and hazard unit PRC8876.

1.

Refer to the workshop manual section 86 for repair information.

2.

Use the vehicle electrical library manual to locate components:

^

Section C547 for hazard unit (Figure 1)

^

Section C570 for the engine compartment fusebox