The plier crimp size is determined by the wire size and insulation diameter.

-

larger wire terminals may have to be crimped with slip joint pliers and soldered

-

Strip approximately 3 mm (1/8 inch) of insulation

-

Insert the appropriate terminal into the special crimping pliers partially close plier to hold terminal

-

Insert stripped wire into terminal and firmly close plier

-

Repeat procedure for insulation crimp

-

Test crimp by applying a pull of 30 Newtons (approx. 7.0 lbs.)

HEAT SHRINKABLE TUBING

The use of heat shrinkable tubing insulation on terminals and wiring repair is recommended. This will ensure that the repair will be properly insulated
and will match the factory wiring.

The correct diameter heat shrinkable tubing is cut to length and installed over the terminal and wire. The length of the tubing should be long enough to
insulate the terminal and extend over the wire insulation approximately 12.5 mm (1/2 inch). The tubing should then be shrunk to a tight fit using a heat
gun as shown. Care should be taken not to overheat or burn this shrink tubing.

Heat shrinkable tubing is available locally in various lengths and diameters.